If your blast chiller keeps losing gas and needs regassing again and again, it has a leak, and a top-up only replaces gas that has already escaped. The real fix is to find the leak, repair it, prove the repair holds, and only then recharge. If a leak is found during a leak check, UK F-Gas rules say it must be repaired as soon as possible.

Why topping up isn’t a fix

Refrigerant isn’t used up like fuel. If your chiller keeps running low, the gas is escaping, and a top-up only works until it escapes again. Meanwhile:

Why blast chillers leak more than most

A blast chiller works harder than almost anything else in your kitchen:

That’s wear from the job, not a badly made chiller. If you’re also seeing warm freezers, our guide to a freezer breakdown covers the warning signs.

What a proper repair looks like

Blast chiller opened up for a nitrogen pressure leak test, with the nitrogen cylinder and hose connected
A blast chiller opened up for a nitrogen pressure leak test.

This photo is from one of our blast chiller jobs: the unit is opened up, with an oxygen-free nitrogen cylinder and hose connected for a pressure leak test. A proper repair goes like this:

  1. Recover the remaining gas. Any refrigerant left in the system is safely recovered, never vented.
  2. Pressure test with nitrogen. The system is filled with oxygen-free nitrogen and the gauge is watched. If the pressure drops, there’s a leak, and the engineer tracks it down. No refrigerant is wasted while hunting for the fault. Industry guidance such as REFCOM TB017 covers how to allow for temperature changes during the test.
  3. Repair the leak. The leaking joint, pipe or part is fixed or replaced.
  4. Retest. The system is pressurised with nitrogen again. If the pressure holds, the system is tight.
  5. Evacuate. A vacuum pump removes the nitrogen, air and moisture.
  6. Recharge. The right type and amount of refrigerant goes back in, and the engineer checks the chiller pulls down properly.
  7. Record it. The engineer writes down what was found, what was done and how much gas went in.

It takes longer than a top-up, but it’s the difference between a repair and a return visit. For more on the units we look after, see our blast chiller repair page.

What the law says

GOV.UK guidance on checking F-gas equipment for leaks is clear: if you find a leak during a check, “you must repair it as soon as possible and repeat the test within a month to check the repair worked.”

Questions to ask your engineer

If the answer to “where was the leak?” is “we just topped it up”, the problem is still there.

The paperwork to expect

After a leak repair, you should get a written job report showing:

Keep it with your F-Gas and food safety records.

What to do next

Blast chiller losing gas or not pulling down?

Frequently asked questions

Why does my blast chiller keep losing gas?

Because it has a leak, usually at a joint, pipe or part stressed by daily hot-to-cold cycles, door openings and vibration.

Is it legal to just keep topping up a leaking blast chiller?

If a leak is found during a check, the law says it must be repaired as soon as possible and rechecked within a month. A top-up on its own doesn’t repair anything.

Can I keep using my blast chiller while it’s low on gas?

Only if it’s still chilling food within your safe chilling times. Check your cooling records and probe readings. If food is taking longer to chill, don’t rely on the chiller until it’s repaired.